changeset 4039:e82257ed348c

[project @ 2002-08-14 19:33:31 by jwe]
author jwe
date Wed, 14 Aug 2002 19:33:31 +0000
parents 243f50d6f3d5
children 5b781670e9ee
files libcruft/dasrt/dasrt_xerrwv.f libcruft/dasrt/xerrwv.f
diffstat 2 files changed, 69 insertions(+), 69 deletions(-) [+]
line wrap: on
line diff
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/libcruft/dasrt/dasrt_xerrwv.f	Wed Aug 14 19:33:31 2002 +0000
@@ -0,0 +1,69 @@
+      SUBROUTINE DASRT_XERRWV (MSG, NMES, NERR, LEVEL, NI, I1, I2,
+     $     NR, R1, R2)
+      INTEGER NMES, NERR, LEVEL, NI, I1, I2, NR
+      DOUBLE PRECISION R1, R2
+      CHARACTER*1 MSG(NMES)
+C-----------------------------------------------------------------------
+C Subroutine XERRWV, as given here, constitutes a simplified version of
+C the SLATEC error handling package.
+C Written by A. C. Hindmarsh and P. N. Brown at LLNL.
+C Modified 1/8/90 by Clement Ulrich at LLNL.
+C Version of 8 January, 1990.
+C This version is in double precision.
+C
+C All arguments are input arguments.
+C
+C MSG    = The message (character array).
+C NMES   = The length of MSG (number of characters).
+C NERR   = The error number (not used).
+C LEVEL  = The error level..
+C          0 or 1 means recoverable (control returns to caller).
+C          2 means fatal (run is aborted--see note below).
+C NI     = Number of integers (0, 1, or 2) to be printed with message.
+C I1,I2  = Integers to be printed, depending on NI.
+C NR     = Number of reals (0, 1, or 2) to be printed with message.
+C R1,R2  = Reals to be printed, depending on NR.
+C
+C Note..  this routine is compatible with ANSI-77; however the
+C following assumptions may not be valid for some machines:
+C
+C 1. The argument MSG is assumed to be of type CHARACTER, and
+C    the message is printed with a format of (1X,80A1).
+C 2. The message is assumed to take only one line.
+C    Multi-line messages are generated by repeated calls.
+C 3. If LEVEL = 2, control passes to the statement STOP
+C    to abort the run.  For a different run-abort command,
+C    change the statement following statement 100 at the end.
+C 4. R1 and R2 are assumed to be in double precision and are printed
+C    in E21.13 format.
+C 5. The logical unit number 6 is standard output.
+C    For a different default logical unit number, change the assignment
+C    statement for LUNIT below.
+C
+C-----------------------------------------------------------------------
+C Subroutines called by XERRWV.. None
+C Function routines called by XERRWV.. None
+C-----------------------------------------------------------------------
+C
+      INTEGER I, LUNIT, MESFLG
+C
+C Define message print flag and logical unit number. -------------------
+      MESFLG = 1
+      LUNIT = 6
+      IF (MESFLG .EQ. 0) GO TO 100
+C Write the message. ---------------------------------------------------
+      WRITE (LUNIT,10) (MSG(I),I=1,NMES)
+ 10   FORMAT(1X,80A1)
+      IF (NI .EQ. 1) WRITE (LUNIT, 20) I1
+ 20   FORMAT(6X,'In above message,  I1 =',I10)
+      IF (NI .EQ. 2) WRITE (LUNIT, 30) I1,I2
+ 30   FORMAT(6X,'In above message,  I1 =',I10,3X,'I2 =',I10)
+      IF (NR .EQ. 1) WRITE (LUNIT, 40) R1
+ 40   FORMAT(6X,'In above message,  R1 =',E21.13)
+      IF (NR .EQ. 2) WRITE (LUNIT, 50) R1,R2
+ 50   FORMAT(6X,'In above,  R1 =',E21.13,3X,'R2 =',E21.13)
+C Abort the run if LEVEL = 2. ------------------------------------------
+ 100  IF (LEVEL .NE. 2) RETURN
+      STOP
+C----------------------- End of Subroutine XERRWV ----------------------
+      END
--- a/libcruft/dasrt/xerrwv.f	Wed Aug 14 19:31:19 2002 +0000
+++ /dev/null	Thu Jan 01 00:00:00 1970 +0000
@@ -1,69 +0,0 @@
-      SUBROUTINE DASRT_XERRWV (MSG, NMES, NERR, LEVEL, NI, I1, I2,
-     $     NR, R1, R2)
-      INTEGER NMES, NERR, LEVEL, NI, I1, I2, NR
-      DOUBLE PRECISION R1, R2
-      CHARACTER*1 MSG(NMES)
-C-----------------------------------------------------------------------
-C Subroutine XERRWV, as given here, constitutes a simplified version of
-C the SLATEC error handling package.
-C Written by A. C. Hindmarsh and P. N. Brown at LLNL.
-C Modified 1/8/90 by Clement Ulrich at LLNL.
-C Version of 8 January, 1990.
-C This version is in double precision.
-C
-C All arguments are input arguments.
-C
-C MSG    = The message (character array).
-C NMES   = The length of MSG (number of characters).
-C NERR   = The error number (not used).
-C LEVEL  = The error level..
-C          0 or 1 means recoverable (control returns to caller).
-C          2 means fatal (run is aborted--see note below).
-C NI     = Number of integers (0, 1, or 2) to be printed with message.
-C I1,I2  = Integers to be printed, depending on NI.
-C NR     = Number of reals (0, 1, or 2) to be printed with message.
-C R1,R2  = Reals to be printed, depending on NR.
-C
-C Note..  this routine is compatible with ANSI-77; however the
-C following assumptions may not be valid for some machines:
-C
-C 1. The argument MSG is assumed to be of type CHARACTER, and
-C    the message is printed with a format of (1X,80A1).
-C 2. The message is assumed to take only one line.
-C    Multi-line messages are generated by repeated calls.
-C 3. If LEVEL = 2, control passes to the statement STOP
-C    to abort the run.  For a different run-abort command,
-C    change the statement following statement 100 at the end.
-C 4. R1 and R2 are assumed to be in double precision and are printed
-C    in E21.13 format.
-C 5. The logical unit number 6 is standard output.
-C    For a different default logical unit number, change the assignment
-C    statement for LUNIT below.
-C
-C-----------------------------------------------------------------------
-C Subroutines called by XERRWV.. None
-C Function routines called by XERRWV.. None
-C-----------------------------------------------------------------------
-C
-      INTEGER I, LUNIT, MESFLG
-C
-C Define message print flag and logical unit number. -------------------
-      MESFLG = 1
-      LUNIT = 6
-      IF (MESFLG .EQ. 0) GO TO 100
-C Write the message. ---------------------------------------------------
-      WRITE (LUNIT,10) (MSG(I),I=1,NMES)
- 10   FORMAT(1X,80A1)
-      IF (NI .EQ. 1) WRITE (LUNIT, 20) I1
- 20   FORMAT(6X,'In above message,  I1 =',I10)
-      IF (NI .EQ. 2) WRITE (LUNIT, 30) I1,I2
- 30   FORMAT(6X,'In above message,  I1 =',I10,3X,'I2 =',I10)
-      IF (NR .EQ. 1) WRITE (LUNIT, 40) R1
- 40   FORMAT(6X,'In above message,  R1 =',E21.13)
-      IF (NR .EQ. 2) WRITE (LUNIT, 50) R1,R2
- 50   FORMAT(6X,'In above,  R1 =',E21.13,3X,'R2 =',E21.13)
-C Abort the run if LEVEL = 2. ------------------------------------------
- 100  IF (LEVEL .NE. 2) RETURN
-      STOP
-C----------------------- End of Subroutine XERRWV ----------------------
-      END